3 Data export software on CD-ROM and a USB A/B cord. 4 One tripod cable with mains plug (adapted to the country of sale. 5 One tripod cable, 3 safety leads. 6 Three probe tips (red, blue, and green). 7 Three crocodile clips (red, blue, and green). 8 Two elbowed-straight safety leads (red and black). 9 One 4-point hands-free strap. If you buy a minimum of 3 pieces of Chauvin Arnoux P01191303 BATTERY TESTER CA 6630 we can offer you a price of 838,57 EUR per piece. The more you buy, the cheaper the article will be. You can also send us a price proposal for your desired quantity of Chauvin Arnoux P01191303 BATTERY TESTER CA 6630 via the form price proposal.
CA 6115 Installation Testers
Inside its worksite case, the CA 6115 is a compact electrical installation tester for taking all measurements to comply with NF C15-100.
Large, backlit LCD display.
Powered by a rechargeable Ni / MH battery. It has a memory capable of storing 800 measurements, as well as an RS 232 interface.
For measuring insulation, RCDs, earth, loop, continuity, phase sequence and current and current leakage measurements using a clamp.
For testing and certifying installations according to NF C 15-100.
Voltage range: | 5 → 440 Vac and Vdc ±1 % |
Current range: | 4 mA → 300 A (with clamp) ±2% |
Frequency range: | 15.3 Hz → 450 Hz ±0.1% |
Insulation (IEC 61557-2): | |
Nominal voltage: | 100 - 250 - 500 VDC |
Range: | 0.05 → 300 MΩ / 600 MΩ ±6% |
Nominal current: | >1 mA |
Earth (IEC 61557-5): | |
Supply: | 95 → 145 Vac / 175 → 300 Vac |
Frequency: | 15.3 → 17.5 Hz / 45 → 65 Hz |
Range: | 0.15 Ω → 10 kΩ ±10% |
Continuity (IEC 61557-4): | |
Test voltage: | 18 Vdc |
Nominal current: | > 200 mA up to 10 W |
Range: | 0.12 Ω → 2 kΩ ±5% |
Loop (IEC 61557-3): | |
Supply: | 95 → 145 Vac / 175 → 300 Vac 330 → 440 Vac |
Frequency: | 15.3 → 17.5 Hz / 45 → 65 Hz |
Range: | 0.12 Ω → 200 Ω ±10% |
Short-circuit current calculation: | 2 A → 30 kA |
RCD (IEC 61557-6): | |
Supply: | 95 → 145 Vac / 175 → 300 Vac |
Frequency: | 15.3 → 17.5 Hz / 45 → 65 Hz |
Rating: | 10 - 30 - 100 - 300 - 500 mA or 6 → 1000 mA (steps of 1 mA) |
Test: | IN / 2, IN, 2IN, 5IN or, ramp from 0.5 → 1.05 IN |
Phase sequence (IEC 61557-7): | |
Supply: | 20 → 440 Vac |
Frequency: | 15.3 → 420 Hz |
Dimensions (mm): | 295 x 230 x 108 |
Weight: | 2100 g |
Standards
IEC 1010-1 Cat. III - 300 V
Attribute | Value |
---|---|
Tester Type | Insulation & Continuity Tester |
Minimum Test Voltage | 100V |
Maximum Test Voltage | 500V |
Maximum Insulation Resistance Measurement | 600MΩ |
Display Type | LCD |
Test Current | 200mA |
Minimum Operating Temperature | -10°C |
Maximum Operating Temperature | +55°C |
Power Source | Battery |
Safety Category Level | CAT III |
Safety Category Voltage | 300V |
Safety Category | CAT III 300 V |
Battery Type | Rechargeable NiMH |
Length | 295mm |
Model Number p | C.A 6115 |
Width | 230mm |
Weight | 2.1kg |
Height | 108mm |
Dimensions | 295 x 230 x 108mm |
CA8334 Power Quality Analyser
Designed for energy supply departments and electrical maintenance services in industrial and administrative buildings, the QualiSTAR 3 Power Quality analyser combines the functionality of a powerful troubleshooting test meter with true power quality meter features.
Includes an oscilloscope and data logger
Easy to use menu driven unit
Rugged handheld unit gives the user a clear visual display of all voltage and current waveforms, which include a vector diagram of imbalance on each of the phase voltages
Fast identification of power quality problems, including harmonics - up to the 50th Order, flicker, interruptions - with adjustable thresholds, dips and frequency
Power/energy mode provided full monitoring of such parameters as W, Var, VA, Wh, Warh, Wah, PF and DPF
Carry case for 'hands free’ operation (included)
4MB of memory, allows assessment of voltage quality parameters according to EN50160 and the recording of voltage and current, power and flicker to identify intermittent problems chart and multi parameters display
50 transients can be captured, each at the sampling rate 12.8kHz, storage of 4 periods of time waveform are displayed with 256 counts per period
The Alarm Mode provides a trigger on different thresholds for any chosen parameter
Collected data can be analysed directly within the QualiSTAR
Data and captured “screen shots” can be downloaded via the optical RS-232 to the QualistarView Window software (provided) for detailed analysis
12 coloured screenshots can be stored and printed directly from a suitable serial printer
Supplied with a 3800mAh NiMH rechargeable battery. The unit may also be mains powered for continuous use whilst charging
Complies with IEC 61010-1, 600V CATIV, pollution degree 2
Choice of AC current sensors pack available separately to suit most applications
Ampflex clamps: Set of 3 reading from 10 to 3000Aac (10Hz to 100Hz) 140mm dia.
MN93 clamps: Set of 3 reading from 2 to 240Aac (48 to 65Hz) 20mm dia.
Selectable scaling for other AC current transformer inputs is provided
Principal values computed:
The text includes: Coverage of the 2005 CPR and ECC Guidelines; Current information on injuries and illnesses: Core information for first aiders presented in a clear and straightforward format; Skill Drills offering step-by-step explanations and visual summaries of important skills; Flowcharts reinforcing the decision-making process and appropriate procedures; and Decision Tables providing a concise summary of what signs first aiders should look for and what treatment steps they should take. Essential orthopedics j maheshwari pdf. Essential Orthopaedics and Trauma 5th Edition PDF Essential Orthopaedics and Trauma 5th Edition PDF Free Download Essential Orthopaedics and Trauma 5th Edition PDF Ebook. Book Description First Aid and CPR Essentials Fifth Edition is the center of an integrated teaching and learning system that offers instructor student and technology resources to better support instructors and prepare students.
Neutral current
Crest factors for current and voltage
K factors for current (transformer application)
Power factor, displacement factor and tangent
Short-term voltage flicker
Voltage and current unbalance
Total harmonic distortion
Average, min and max values of any computed value
Safety | EN IEC 61010 |
Power Measurements | 0 to 9999KW (Active); 0 to 9999KVAR (Reactive); 0 to 9999KVA (Apparent) |
Power Resolution | 4 digits |
Memory (Test results) | Yes |
Power Factor | -1 to +1 |
Resolution ac Current | 0.1A (if >1000 A, rms); 1 A (if >1000 A, rms) |
Accuracy ac Current | ±(0.5% +0.2 A) (rms) |
Resolution dc Current | 0.1A (if >1000 A, rms); 1 A (if >1000 A, rms) |
Accuracy dc Current | ±( (0.5% +0.2A) (rms) |
Maximum ac Voltage | 480Vrms (Single Phase); 800 Vrms (Phase - Phase) |
Resolution ac Voltage | 0.1V (rms) |
Accuracy ac Voltage (V, mV) | ±( (0.5% +0.5V) (rms) |
Maximum dc Voltage | 480 Vrms (Single Phase); 800 Vrms (Phase - Phase) |
Accuracy dc Voltage (mV, V, Percent) | ±( (0.5% +0.5V) (rms) |
Size (HxWxD) and Weight | 240 x 180 x 55mm, 1.5g |
Note
Chauvin Arnoux Ca 6115n Manual: Software free. download full
Calibration certificate contains measurements made using unity power factor only.
Chauvin Arnoux Ca 6115n Manual: software, free download 2017
Supplied with
QualistarView software, DB9F optical RS-232 lead, 4 off 3m leads fitted with 4mm plugs, 4 crocodile clips, 1 mains lead, 1 user’s manual, 1 soft carry case.
Chauvin Arnoux Ca 6115n Manual: software, free download Free
Attribute | Value |
---|---|
Absolute Maximum Power Measurement | 9999kW |
Number of Phases | 3 |
Maximum Voltage | 600V |
Best Voltage Measurement Accuracy | ±0.5 % |
Best Current Measurement Accuracy | ±0.5 % |
Calibrated | SYSCAL |
Display Type | LCD |
Measurement Type | Energy, Frequency, Harmonics, Peak Current, Peak Voltage, TRMS Current, TRMS Voltage |
Measurement Standards | EN50160 |
Interface Type | RS232 |
Memory Capacity | 4MB |
Power Source | Battery |
Battery Type | Rechargeable NiMH |
Height | 55mm |
Weight | 1.5kg |
Minimum Operating Temperature | 0°C |
Maximum Operating Temperature | +50°C |
Minimum Frequency | 40 Hz |
Maximum Frequency | 70Hz |
Dimensions | 180 x 240 x 55mm |
Model Number p | C.A 8334 |
Length | 180mm |
Width | 240mm |